Your Home Energy Station
-
Blackout Power: Use your EV’s battery to sail through multi-day utility grid outages
-
Solar Charging: Charge your EV with the unlimited, free power of the sun
-
Power Boost: One mile of range per minute of charge
-
Orchestrate OS: Unique operating system that minimizes your energy costs and carbon footprint
-
Dual Charge: Charge two EVs at once
-
Easy Outdoor or Indoor Installation: Installed by a single technician
A SINGLE DCBEL REPLACES THE FOLLOWING EQUIPMENT:
- Fast DC bidirectional electric vehicle charger
- Level 2 electric vehicle charger
- Solar inverter
- Stationary battery charger / inverter
- Smart home energy manager
DC Fast EV Charger
|
|
Connectors
|
CHAdeMO / CCS
|
AC Inputs
|
|
Nominal Voltage (V)
|
240 Single Phase or + 120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
64
|
Frequency (Hz)
|
60 (50 capable)
|
DC Outputs
|
|
Nominal Power @400V (kW)
|
15.2
|
Nominal Voltage (V)
|
400
|
Voltage Range (V)
|
150-500
|
Nominal Current (A)
|
38
|
Max Efficiency (%)
|
96.3
|
Voltage Ripple (%)
|
< 2.5
|
EV Inverter (V2H / V2G)?
|
|
Connectors
|
CHAdeMO / CCS ?
|
DC Inputs
|
|
Nominal Voltage (kV)
|
400
|
Voltage Range (V)
|
150-500
|
Nominal Current (A)
|
19 / 38 ?
|
AC Outputs
|
|
Nominal Power (kW)
|
7.6 / 15.2 ?
|
Nominal Voltage (V)
|
240 Single Phase or + 120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
32 / 64 ?
|
Frequency (Hz)
|
60 (50 capable)
|
Max Efficiency (%)
|
98.4
|
Power factor (%)
|
> 99
|
THD (%)
|
< 3
|
Grid Forming
|
True Sine Wave
|
Solar Inverter
|
|
DC Inputs
|
|
Max PV Power (kWp)
|
10 / 20 ?
|
Open Circuit Voltage (Voc)
|
500
|
MPPT operating range (V)
|
240-500
|
Nominal Voltage (V)
|
400
|
Short Circuit Current (A)
|
36 per MPPT
|
Max Current (A)
|
19 per MPPT ?
|
Number of MPPT Channels
|
1 / 2 ?
|
AC Outputs
|
|
Nominal Power (kW)
|
7.6 / 15.2 ?
|
Nominal Voltage (V)
|
240 Single Phase or + 120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
32 / 64 ?
|
Nominal Frequency (Hz)
|
60 (50 capable)
|
Max Efficiency (%)
|
98.4
|
Power factor (%)
|
> 99
|
THD (%)
|
< 3
|
AC Level 2 EV Charger
|
|
Connector
|
J1772
|
Nominal Output Power (kW)
|
9.2
|
Nominal Voltage (V)
|
240 Single Phase or + 120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
38
|
General
|
|
Dimensions
|
|
Height (in / mm)
|
31.5 / 800
|
Width (in / mm)
|
19.7 / 500
|
Depth (in / mm)
|
9.1 / 230
|
Total Weight (lbs / kg)
|
< 62 / < 28
|
Max Component Module Weight (lbs / kg)
|
35 / 16
|
Standby Monitoring Power Consumption (W)
|
< 30
|
Communication
|
RJ45 – TCP/IP ready
|
Operating Temperature (°F/°C)
|
-13 to 113 / -25 to 45
|
Enclosure
|
NEMA 3R, IP54, UL94 5VB
|
Certification
|
UL 9741, 2594, 2231-1, 2231-2, 1741 SA, IEEE 1547, FCC Part 15 (pending)
|
Security Certification
|
CC Certified (TPM 2.0 at EAL4+) & FIPS 140-2 Level 1 & 2
|
AC Connection: Breaker Size Recommendation
|
|
Installation with Blackout Power
|
|
DC Charger, Solar Inverter, V2H/V2G, ESS (A) (Double-pole breaker in main panel)
|
175 or 125 ?
(including subpanel house load)
|
EV AC Charger (A) (Double-pole breaker in subpanel)
|
50
|
UPS connected to wall socket (A) (Single-pole breaker in subpanel)
|
15
|
Installation without Blackout Power
|
|
DC Charger, Solar Inverter, V2H/V2G, ESS (A) (Double-pole breaker in main panel)
|
2 x 40
|
EV AC Charger (A) (Double-pole breaker in main panel)
|
50
|
Power Supply (A) (Plug into wall socket or single-pole breaker in main panel)
|
15
|
Stationary Battery
|
|
Communication
|
RS485
|
Charging Mode
|
|
AC Inputs
|
|
Nominal Voltage (V)
|
240 Single Phase or +120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
32
|
Frequency (Hz)
|
60 (50 capable)
|
DC Outputs
|
|
Nominal Power (kW)
|
7.6
|
Nominal Voltage (V)
|
400
|
Voltage Range (V)
|
240-500
|
Nominal Current (A)
|
19
|
Max Efficiency (%)
|
96.3
|
Voltage Ripple (%)
|
2.5
|
Discharging Mode
|
|
DC Inputs
|
|
Nominal Voltage (V)
|
400
|
Voltage Range (V)
|
240-500
|
Nominal Current (A)
|
19
|
AC Outputs
|
|
Nominal Power (kW)
|
7.6
|
Nominal Voltage (V)
|
240 Single Phase or +120/-120 Split Phase
|
Voltage Range (V)
|
208-254
|
Nominal Current (A)
|
32
|
Frequency (Hz)
|
60 (50 capable)
|
Max Efficiency (%)
|
98.4
|
Power factor (%)
|
> 99
|
THD (%)
|
< 3
|
Grid Forming
|
True Sine Wave
|
AC Output (dcbel to Home)
|
|
Nominal Output Power (kW)
|
15.2
|
Nominal Output Voltage (V)
|
240 Single Phase or + 120/-120 Split Phase
|
Output Voltage Range (V)
|
208-254
|
Nominal Output Current (A)
|
64
|
Frequency (Hz)
|
60 (50 capable)
|
BLACKOUT POWER KIT
Power Kit
|
|
dcbel aTS (Automatic Transfer Switch)
|
|
Communication
|
RS485
|
Relay Rated Current (A)
|
200
|
Height (in / mm)
|
24 / 610
|
Width (in / mm)
|
18.5 / 470
|
Depth (in / mm)
|
6 / 152
|
Installation
|
Indoor only
|
UPS Power Module(s)
|
|
Installation with Stationary Battery
|
|
Backup Time (Mins)
|
9
|
Height (in / mm)
|
4.3 / 110
|
Width (in / mm)
|
6.3 / 160
|
Depth (in / mm)
|
11.8 / 300
|
Installation
|
Indoor only
|
Installation without Stationary Battery
|
|
Backup Time (Hours)
|
6
|
Height (in / mm)
|
11.8 / 300
|
Width (in / mm)
|
7 / 180
|
Depth (in / mm)
|
7.4 / 190
|
Installation
|
Indoor only
|
SUPPORTING HARDWARE
dcbel aT (Autotransformer)
|
|
Power (kW)
|
7.6
|
Voltage (V ac)
|
240:120V ac split-phase
|
Height (in / mm)
|
15.7 / 399
|
Width (in / mm)
|
12.6 / 320
|
Depth (in / mm)
|
6.3 / 160
|
Installation
|
Indoor only
|
STANDARD DCBEL EQUIPMENT
Tempo (Home Current Sensor)
|
|
AC Sensor
|
2 CT Clamps
|
Communication
|
RS485
|
Rated Current (A)
|
200
|
Height (in / mm)
|
2.9 / 74
|
Width (in / mm)
|
6.1 / 155
|
Depth (in / mm)
|
1.5 / 40
|
Installation
|
Indoor only
|
DCBEL INSTALLATION SINGLE LINE DIAGRAM
DCBEL INSTALLATION WIRING DIAGRAM
-
1 EVAC SAE J1772 Type 1 EV Connector
-
2 EVDC CHAdeMO or CCS1 EV Connector
-
3 AC1 and AC2 PUC5 1, PUC5 2 and Power Supply
-
4 AC3 EVAC Grid Input
-
5 ESS and PV PV1 and Stationary Battery Power Cables
-
6 COM Stationary Battery, Tempo, Ethernet and ATS Communication Cables